Lorem ipsum dolor sit amet, consectetur adipiscing elit. Aenean feugiat dictum lacus, ut hendrerit mi pulvinar vel. Fusce id nibh at neque eleifend tristique at sit amet libero. In aliquam in nisl nec sollicitudin. Sed consectetur volutpat sem vitae facilisis. Fusce tristique, magna ornare facilisis sagittis, tortor mi auctor libero, non pharetra sem ex eu felis. Aenean egestas ut purus nec vehicula. Morbi eu nisi erat. Nam mattis id lectus sit amet mattis. Suspendisse eget tristique neque

Working Hours

Monday - Friday 09:00AM-17:00PM
Saturday - Sunday CLOSED

Latest News

    No posts were found.

Top

Validation of Smartphone Based Retinal Photography for Diabetic Retinopathy Screening

plosoNE

Aim

To evaluate the sensitivity and specificity of “fundus on phone’ (FOP) camera, a smartphone based retinal imaging system, as a screening tool for diabetic retinopathy (DR) detection and DR severity in comparison with 7-standard field digital retinal photography.

Design

Single-site, prospective, comparative, instrument validation study.

Methods

301 patients (602 eyes) with type 2 diabetes underwent standard seven-field digital fundus photography with both Carl Zeiss fundus camera and indigenous FOP at a tertiary care diabetes centre in South India. Grading of DR was performed by two independent retina specialists using modified Early Treatment of Diabetic Retinopathy Study grading system. Sight threatening DR (STDR) was defined by the presence of proliferative DR(PDR) or diabetic macular edema. The sensitivity, specificity and image quality were assessed.

Results

The mean age of the participants was 53.5 ±9.6 years and mean duration of diabetes 12.5±7.3 years. The Zeiss camera showed that 43.9% had non-proliferative DR(NPDR) and 15.3% had PDR while the FOP camera showed that 40.2% had NPDR and 15.3% had PDR. The sensitivity and specificity for detecting any DR by FOP was 92.7% (95%CI 87.8–96.1) and 98.4% (95%CI 94.3–99.8) respectively and the kappa (ĸ) agreement was 0.90 (95%CI-0.85–0.95 p<0.001) while for STDR, the sensitivity was 87.9% (95%CI 83.2–92.9), specificity 94.9% (95%CI 89.7–98.2) and ĸ agreement was 0.80 (95%CI 0.71–0.89 p<0.001), compared to conventional photography.

Conclusion

Retinal photography using FOP camera is effective for screening and diagnosis of DR and STDR with high sensitivity and specificity and has substantial agreement with conventional retinal photography.

**

Link to Scientific Publication in PLOSOne